Skip to main content
Addgene
Showing: 71 - 80 of 110 results
  1. March for Science

    Type
    Blog Post
    ... 15-008: Perspectives on Broader Impacts. The Pipettepen: The March for Science Raises Concerns Over Politicization...
  2. Antibodies 101: Flow Cytometry

    Type
    Blog Post
    ...keep samples on ice at all times and use gentle pipetting instead of vortexing. Include proper controls ...
  3. Lentiviral Vector Guide

    Type
    Guide
    ... development of multiple genome-wide analysis pipelines to assess viral integration (see Kim et al. (2021... Hughes, S. H., & Wu, X. (2020). An analytical pipeline for identifying and mapping the integration sites...
  4. Pipetting Protocol

    Type
    Protocol
    ...the correct pipettor and pipette tip, how to dispense liquids, and how to handle the pipette....you in selecting the correct pipette and pipette tip and using the pipette. Last Update: September 2022...Watch the video for tips on pipetting in the lab. Equipment Pipettes Pipette tips Waste container Containers...for pipetting Background Information Anatomy of a Pipette This front view photo of a P1000 pipette shows...which pushes the pipette tip off of the pipette. This side view photo of a P1000 pipette shows the volume... tip ejector down the pipette to remove the tip. Choosing a Pipette and Pipette Tips Although there are...idea of what pipette to use with it. The purpose of the pipette tip is so that the same pipette can be used...
  5. Molecular Biology Reference

    Type
    Guide
    ...DYKDDDDK HA YPYDVPDYA His HHHHHH Myc EQKLISEEDL V5 GKPIPNPLLGLDST Xpress DLDDDDK or DLYDDDDK Thrombin LVPRGS ...
  6. AAV ddPCR Titration

    Type
    Protocol
    ...single channel pipette 20–200 µL single channel pipette 200–1000 µL single channel pipette 1–10 µL multichannel...multichannel pipette 2–50 µL multichannel pipette 20–200 µL multichannel pipette Vortex, VWR, 10153-688 Mini...and pipette 5–10 times to mix. Dilute the virus as follows: Mix dilutions thoroughly, but pipette slowly...multichannel pipettes for the dilution series. For dilutions 1–5, use the 1–10 µL multichannel pipette set to...multichannel pipette set to 50 µL. For mixing between dilutions, use the 20–200 µL multichannel pipette set to...primers, and probe on ice before use. Wipe down all pipettes and surfaces with 10% bleach. Safety Warnings ...droplet generation are supplied with sufficient pipette tips and reagent reservoirs. Pro-Tip Prepare the...
  7. Lentivirus ddPCR Titration

    Type
    Protocol
    ...single channel pipette 20–200 µL single channel pipette 200–1000 µL single channel pipette 2–50 µL multichannel...diluent, pipette 10 times, to remove virus from pipette tip. To mix the dilution, set the P200 pipette to 200...multichannel pipette 20–200 µL multichannel pipette Ice bucket 96-well freezer blocks Vortex, VWR, 10153-... 200 µL and pipette 10–20 times. Use a new pipette tip to transfer 200 µL of the first dilution into the...mixes and samples on ice before use. Wipe down all pipettes and surfaces with 10% bleach. Safety Warnings ...well before seeding. Mix each well with a 1 mL pipette 5–10 times. The final volume in the well is 1.5...6-well plates. Be sure to use a new aspirating pipette for each well as to not contaminate cell conditions...
  8. Antibody Validation Using the Indirect ELISA Method

    Type
    Protocol
    ...channel pipette 20–200 µL multichannel pipette Multichannel pipette reagent reservoirs Pipette controller...single channel pipette 2–20 µL single channel pipette 20–200 µL single channel pipette 200–1000 µL single...Neptune 3745.X Pipette tips, 1000 µL, VWR 76322-154 Pipette tips, 10 µL, VWR 76322-132 Pipette tips, 200 µL... µL, VWR 76322-150 Pipette tips, 20 µL, VWR 76322-134 Pipettes, 10 mL, VWR 89130-898 1 L polystyrene bottle...microfuge tube and vortex. 0 ng/µL : 450 µL PBS only. Pipette 50 µL into the first three wells of each row, using...wash buffer (0.05% Tween-20 in PBS) as follows: Pipette 0.5 mL of Tween-20 to into 999.5 mL 1X PBS Cap ...aside. Aspirate the wells and use a multichannel pipette to add 200 µL wash buffer to each well. Washing...
  9. AAV Titration by qPCR Using SYBR Green Technology

    Type
    Protocol
    ...Heating plate Pipettors 1–10 µL single channel pipette 20–200 µL single channel pipette 200–1000 µL single...single channel pipette 1–10 µL multichannel pipette 2–50 µL multichannel pipette 20–200 µL multichannel...multichannel pipet to minimize pipetting error and variability Mix samples very well by pipetting back and...multichannel pipette Reagents Universal SYBR Master Mix 2X Primer pair targeting AAV2 ITR ( Aurnhammer et al., ...water Microcentrifuge tubes 96-well optical plate Pipette tips General Considerations Always run standards...that result from a variety of causes, such as pipetting error and sample evaporation. Make the master ...before use. Use a reservoir and a multichannel pipette to dispense the master mix into the wells. Reagent...
Showing: 71 - 80 of 110 results