Skip to main content

We narrowed to 1,001 results for: Mpl

Showing: 921 - 940 of 1001 results
  1. Centrifugation

    Type
    Protocol
    ... which you need to spin your samples. For example, spinning down samples in 1.5 mL microfuge tubes at ...liquid sample. It achieves this by using centrifugal force, which is generated by spinning the sample at ... with water to the same volume as your samples. If your samples are significantly higher density than ...centrifuge to separate different components in a liquid sample. Protocols...RNA extractions. Plus, centrifuges are useful for simply collecting liquid to the bottom of a tube. You ... containers, spin at different speeds, or keep samples at specific temperatures. This protocol will cover...for the biosafety level of the lab space Reagents Sample to be centrifuged Water Background Information ...
  2. Affinity Purification of Recombinant Antibodies with Protein A or Protein G

    Type
    Protocol
    ...finite binding capacity. If your sample exceeds the capacity, divide the sample among multiple columns. For...4 mL of recombinant antibody sample. Pro-Tip If the volume of the sample is greater than 4 mL , then divide... Slowly apply the sample to the center of the compact resin bed. Pro-Tip For sample volumes <1.5 mL top...the sample with 0.2 mL PBS to aid protein recovery. Allow the resin bed to fully absorb the sample. Centrifuge...Spectrophotometer to see if the sample has reached the desired concentration. If the sample concentration is still... to see if the sample has reached the desired concentration. Gently transfer the sample from the reservoir... 250 mL sterile bottle, VWR 430281 0.45 µm PES complete filtration unit, 500 mL, rapid-flow, VWR 73520...
  3. Affinity Purification of Recombinant Antibodies with Protein A or Protein G

    Type
    Protocol
    ...finite binding capacity. If your sample exceeds the capacity, divide the sample among multiple columns. For...4 mL of recombinant antibody sample. Pro-Tip If the volume of the sample is greater than 4 mL , then divide... Slowly apply the sample to the center of the compact resin bed. Pro-Tip For sample volumes <1.5 mL top...the sample with 0.2 mL PBS to aid protein recovery. Allow the resin bed to fully absorb the sample. Centrifuge...Spectrophotometer to see if the sample has reached the desired concentration. If the sample concentration is still... to see if the sample has reached the desired concentration. Gently transfer the sample from the reservoir... 250 mL sterile bottle, VWR 430281 0.45 µm PES complete filtration unit, 500 mL, rapid-flow, VWR 73520...
  4. AAV ddPCR Titration

    Type
    Protocol
    ... ddPCR sample data Sample Dilution Concentration Titer (GC/mL) Average Titer (GC/mL) AAV Sample 1 6400000...tube as shown below. For 8 samples prepare enough master mix for 9 samples. ITR Master Mix Volume 9X Volume...layout is complete, select 'Run' to begin the droplet reading. When the droplet reading is complete, export...prepared for each AAV sample, and the three final dilutions are assayed. The samples that are assayed are...across the dilutions. In the example below, 2-fold serial dilutions of a sample were loaded in wells A04,... higher dilutions depending on their particular sample. For additional tips on AAV titering using ddPCR... on the insert. Please ensure that you are in compliance with your institution’s biosafety regulations...
  5. AAV ddPCR Titration

    Type
    Protocol
    ... ddPCR sample data Sample Dilution Concentration Titer (GC/mL) Average Titer (GC/mL) AAV Sample 1 6400000...tube as shown below. For 8 samples prepare enough master mix for 9 samples. ITR Master Mix Volume 9X Volume...layout is complete, select 'Run' to begin the droplet reading. When the droplet reading is complete, export...prepared for each AAV sample, and the three final dilutions are assayed. The samples that are assayed are...across the dilutions. In the example below, 2-fold serial dilutions of a sample were loaded in wells A04,... higher dilutions depending on their particular sample. For additional tips on AAV titering using ddPCR... on the insert. Please ensure that you are in compliance with your institution’s biosafety regulations...
  6. Protocol - How to Design Primers

    Type
    Protocol
    ...correspond to sequences on the template molecule (must be complementary to template strand). However, primers...One needs to design primers that are complementary to the template region of DNA. They are synthesized ...primers do not need to correspond to the template strand completely; it is essential, however, that the 3’...3’ end of the primer corresponds completely to the template DNA strand so elongation can proceed. Usually...well. Short primers are mainly used for amplifying a small, simple fragment of DNA. On the other hand, a... a long primer is used to amplify a eukaryotic genomic DNA sample. However, a primer should not be too...primers produce inaccurate, nonspecific DNA amplification product, and long primers result in a slower...
  7. Protocol - How to Design Primers

    Type
    Protocol
    ...correspond to sequences on the template molecule (must be complementary to template strand). However, primers...One needs to design primers that are complementary to the template region of DNA. They are synthesized ...primers do not need to correspond to the template strand completely; it is essential, however, that the 3’...3’ end of the primer corresponds completely to the template DNA strand so elongation can proceed. Usually...well. Short primers are mainly used for amplifying a small, simple fragment of DNA. On the other hand, a... a long primer is used to amplify a eukaryotic genomic DNA sample. However, a primer should not be too...primers produce inaccurate, nonspecific DNA amplification product, and long primers result in a slower...
  8. Western Blot

    Type
    Protocol
    ...duplicate samples on the plate. Subtract the average absorbance of the blank from all of the samples. Plot...concentration of the sample from the standard curve. Determine the volume of sample required to load an...protein for each sample. Pro-Tip The ideal total protein loaded will vary between samples and target proteins...abundance in the sample you will need to load a greater amount of total protein. Prepare sample for loading...Dilute 4X protein loading buffer in the sample to 1X . Boil the samples for 10 min at 100 °C . Section 3: SDS-PAGE...blotting to visualize a protein from cells or tissue samples. Equipment Microcentrifuge 0.5–10 µL single channel... the host species of the primary antibody. For example, use an anti-mouse secondary antibody for primary...
  9. Western Blot

    Type
    Protocol
    ...duplicate samples on the plate. Subtract the average absorbance of the blank from all of the samples. Plot...concentration of the sample from the standard curve. Determine the volume of sample required to load an...protein for each sample. Pro-Tip The ideal total protein loaded will vary between samples and target proteins...abundance in the sample you will need to load a greater amount of total protein. Prepare sample for loading...Dilute 4X protein loading buffer in the sample to 1X . Boil the samples for 10 min at 100 °C . Section 3: SDS-PAGE...blotting to visualize a protein from cells or tissue samples. Equipment Microcentrifuge 0.5–10 µL single channel... the host species of the primary antibody. For example, use an anti-mouse secondary antibody for primary...
  10. Plasmid Cloning by PCR (with Protocols)

    Type
    Protocol
    ...to the stop codon (TGA, in this example). Assuming you are amplifying from plasmid DNA (rather than from..., but we need to use the reverse complement to get PCR amplification. We can start similarly, taking ...generate the reverse-complement of this sequence so that we can successfully amplify the ORF. You can generate... to be amplified (the ORF in this case), not the Tm of the entire primer. If you are amplifying from a... a plasmid or simple template, there is very little chance for mis-priming, so you can use a pretty wide...between samples. In addition to a DNA ladder standard, it is also a good idea to run an uncut sample of each...choice with minimal limitations. Background In its simplest form, PCR based cloning is about making a copy...
  11. Plasmid Cloning by PCR (with Protocols)

    Type
    Protocol
    ...to the stop codon (TGA, in this example). Assuming you are amplifying from plasmid DNA (rather than from..., but we need to use the reverse complement to get PCR amplification. We can start similarly, taking ...generate the reverse-complement of this sequence so that we can successfully amplify the ORF. You can generate... to be amplified (the ORF in this case), not the Tm of the entire primer. If you are amplifying from a... a plasmid or simple template, there is very little chance for mis-priming, so you can use a pretty wide...between samples. In addition to a DNA ladder standard, it is also a good idea to run an uncut sample of each...choice with minimal limitations. Background In its simplest form, PCR based cloning is about making a copy...
  12. Protocol - How to Run an Agarose Gel

    Type
    Protocol
    ...steadily, push the sample out and watch as the sample fills the well. After all of the sample is unloaded, .... Loading Samples and Running an Agarose Gel: Add loading buffer to each of your DNA samples and mix well...Note: When loading the sample in the well, maintain positive pressure on the sample to prevent bubbles or...bands needed to be separated - see FAQs below . Simply adjust the mass of agarose in a given volume to...). Microwave for 1-3 min until the agarose is completely dissolved (but do not overboil the solution, ...room temperature for 20-30 mins, until it has completely solidified. Pro-Tip If you are in a hurry, the... well. Use 5 µl of loading buffer per 25 µl of sample. Note: Loading buffer serves two purposes: 1) it...
  13. Protocol - How to Run an Agarose Gel

    Type
    Protocol
    ...steadily, push the sample out and watch as the sample fills the well. After all of the sample is unloaded, .... Loading Samples and Running an Agarose Gel: Add loading buffer to each of your DNA samples and mix well...Note: When loading the sample in the well, maintain positive pressure on the sample to prevent bubbles or...bands needed to be separated - see FAQs below . Simply adjust the mass of agarose in a given volume to...). Microwave for 1-3 min until the agarose is completely dissolved (but do not overboil the solution, ...room temperature for 20-30 mins, until it has completely solidified. Pro-Tip If you are in a hurry, the... well. Use 5 µl of loading buffer per 25 µl of sample. Note: Loading buffer serves two purposes: 1) it...
  14. Ligation Independent Cloning

    Type
    Protocol
    ...sterile dH20 to 40 μl Step 4: Amplify Insert by PCR Perform PCR amplification of your insert following the...through the transformation/replication process. LIC employs long overhangs to form a stable association between...replication cycle. Empty vectors for LIC typically employ type II restriction enzymes (e.g. BsaI), which ...counter-selection for negative clones as in the example shown here. The manufacturer of an LIC-specific...respective primers. Below we use pNIC28-Bsa4 as an example of LIC experimental design. Search Addgene's collection... Your Primers Primer design for LIC is often as simple as using the backbone manufacturer's suggested ...sequence is used, plus a minimum of 18 bp of your template sequence. 5' and 3' primers will have different...
  15. Ligation Independent Cloning

    Type
    Protocol
    ...sterile dH20 to 40 μl Step 4: Amplify Insert by PCR Perform PCR amplification of your insert following the...through the transformation/replication process. LIC employs long overhangs to form a stable association between...replication cycle. Empty vectors for LIC typically employ type II restriction enzymes (e.g. BsaI), which ...counter-selection for negative clones as in the example shown here. The manufacturer of an LIC-specific...respective primers. Below we use pNIC28-Bsa4 as an example of LIC experimental design. Search Addgene's collection... Your Primers Primer design for LIC is often as simple as using the backbone manufacturer's suggested ...sequence is used, plus a minimum of 18 bp of your template sequence. 5' and 3' primers will have different...
  16. AAV Production in HEK293 Cells

    Type
    Protocol
    ... 50% amplitude. Return to ice between each round of sonication to avoid overheating of the sample. Mix... mM NaCl, 2 mM MgCl2) Reagent Preparation DMEM Complete : 10% v/v FBS and 4 mM L-alanyl-L-glutamine (or...min. Neutralize trypsin by adding 10 mL of DMEM Complete. Pipet back and forth vigorously multiple times...-175 flasks. Adjust volume to 300 mL with DMEM complete media and mix. Seed all cells in 1 CS2. Return...CS2 to help detach the cells, add 200 mL of DMEM complete media, then transfer the cells into a sterile ...sterile bottle. Rinse the CS2 with 100 mL of DMEM complete medium and pool with the cells harvested in the previous...0.08 μg/bp Therefore, for each plasmid we need: Sample Calculations RepCap: 0.08 μg/bp × 7,265 bp = 582.1...
  17. AAV Production in HEK293 Cells

    Type
    Protocol
    ... 50% amplitude. Return to ice between each round of sonication to avoid overheating of the sample. Mix... mM NaCl, 2 mM MgCl2) Reagent Preparation DMEM Complete : 10% v/v FBS and 4 mM L-alanyl-L-glutamine (or...min. Neutralize trypsin by adding 10 mL of DMEM Complete. Pipet back and forth vigorously multiple times...-175 flasks. Adjust volume to 300 mL with DMEM complete media and mix. Seed all cells in 1 CS2. Return...CS2 to help detach the cells, add 200 mL of DMEM complete media, then transfer the cells into a sterile ...sterile bottle. Rinse the CS2 with 100 mL of DMEM complete medium and pool with the cells harvested in the previous...0.08 μg/bp Therefore, for each plasmid we need: Sample Calculations RepCap: 0.08 μg/bp × 7,265 bp = 582.1...
  18. Virus Protocol - Generating Stable Cell Lines

    Type
    Protocol
    ...the lentivirus in DMEM complete + 10 µg/mL polybrene. Note, this is just a sample of possible dilutions...puromycin, blasticidin) Reagent Preparation DMEM Complete: 10% v/v FBS and 4 mM L-alanyl-L-glutamine (or...kills all of the cells. Prepare a batch of DMEM complete + 10 µg/mL polybrene by diluting 20 µL of 10 mg...Dilution Volume of Lentivirus (μL) Volume of DMEM complete + 10 µg/mL polybrene (µL) 0 0 500 1:5 300 200 ...,000 cells into a total volume of 7 mL of DMEM complete + 10 µg/mL polybrene. Mix well by pipetting or...all the media in these wells was made with DMEM complete + 10 µg/mL polybrene, the final concentration ...aspirate the media from the cells. Add 1.5 mL of DMEM complete containing the appropriate antibiotic. This is...
  19. Virus Protocol - Generating Stable Cell Lines

    Type
    Protocol
    ...the lentivirus in DMEM complete + 10 µg/mL polybrene. Note, this is just a sample of possible dilutions...puromycin, blasticidin) Reagent Preparation DMEM Complete: 10% v/v FBS and 4 mM L-alanyl-L-glutamine (or...kills all of the cells. Prepare a batch of DMEM complete + 10 µg/mL polybrene by diluting 20 µL of 10 mg...Dilution Volume of Lentivirus (μL) Volume of DMEM complete + 10 µg/mL polybrene (µL) 0 0 500 1:5 300 200 ...,000 cells into a total volume of 7 mL of DMEM complete + 10 µg/mL polybrene. Mix well by pipetting or...all the media in these wells was made with DMEM complete + 10 µg/mL polybrene, the final concentration ...aspirate the media from the cells. Add 1.5 mL of DMEM complete containing the appropriate antibiotic. This is...
  20. Pouring LB Agar Plates

    Type
    Protocol
    ...growth. See our sample data section below for positive and negative test results. Sample Data In all cases...bacteria containing the plasmids of interest (for example, fewer satellite colonies will grow). However, ...on the number of plates you’d like to pour. For example: Because we’d like to make 20 plates, and our plates...will darken during the autoclave process if your sample has spent at least 10 min at 121 ℃. Use lab tape...the autoclave and run on a setting that gets the sample to at least 121 ℃ under 20 psi for at least 30 ... any weird and wonderful organisms. While your samples are sterilizing in the autoclave, you should prepare... you should create a 1000x stock solution. For example: If you’ll be preparing plates with a final concentration...
Showing: 921 - 940 of 1001 results