Skip to main content
Addgene

We narrowed to 35 results for: PIP

Showing: 11 - 20 of 35 results
  1. Fluorescence Titering Assay

    Type
    Protocol
    ...single channel pipette 2–20 µL single channel pipette 20–200 µL single channel pipette 200–1000 µL single...single channel pipette Ice bucket CO 2 incubator Pipet controller Hazardous waste container Inverted fluorescence...cells into 14 mL of DMEM complete. Mix well by pipetting or inverting. Aliquot 2 mL of cell suspension ...
  2. Lentivirus Production

    Type
    Protocol
    ...single channel pipette 2–20 µL single channel pipette 20–200 µL single channel pipette 200–1000 µL single...single channel pipette Ice bucket CO 2 incubator Pipet controller Hazardous waste container pH meter Stir...out of the previously seeded 10 cm plate. Slowly pipette the transfection mix onto the 10 cm plate, being...
  3. Colony Formation Titering Assay

    Type
    Protocol
    ...single channel pipette 2–20 µL single channel pipette 20–200 µL single channel pipette 200–1000 µL single...single channel pipette Ice bucket CO 2 incubator Pipet controller Hazardous waste container Reagents DMEM...complete containing 10 μg/mL polybrene. Mix well by pipetting or inverting. Aliquot 1.35 mL of the cell suspension...
  4. Transfection for Recombinant Antibodies

    Type
    Protocol
    ...Biosafety Cabinet 4 °C Refrigerator Micropipettes and tips Pipettor and pipettes Benchtop centrifuge compatible...Reagent Preparation instructions. Wipe down all pipettes and equipment with 10% bleach prior to use. Reagent...Check the cell density and viability: Using a 5 mL pipette, transfer 0.5 mL of HEK293 cell suspension into...the microfuge tube containing the trypan blue. Pipette 10 times to mix. Load 10 µL of the cell suspension...
  5. Virus Protocol - Generating Stable Cell Lines

    Type
    Protocol
    ...single channel pipette 2–20 µL single channel pipette 20–200 µL single channel pipette 200–1000 µL single...single channel pipette Ice bucket CO 2 incubator Pipet controller Hazardous waste container Reagents DMEM...DMEM complete + 10 µg/mL polybrene. Mix well by pipetting or inverting the tube. Aliquot 1 mL of cell suspension...
  6. Isolating a Monoclonal Cell Population by Limiting Dilution

    Type
    Protocol
    ...single channel pipette 2–20 µL single channel pipette 20–200 µL single channel pipette 200–1000 µL single...single channel pipette CO 2 incubator Pipet controller Hazardous waste container Microscope Hemocytometer... by passing several times through a serological pipet or by passing through a 40 µm cell strainer mesh...
  7. Kit Free RNA Extraction

    Type
    Protocol
    ...storage in the cold room may damage it. Using a pipettor, transfer the top, aqueous phase to a new RNAse-free...disturb or collect the interphase layer with your pipette tip. Pro-Tip To collect as much of the top aqueous...interphase layer, consider using a lower volume pipettor like a p200 to collect a majority of the aqueous...
  8. Protocol - Over-Agar Antibiotic Plating

    Type
    Protocol
    ...spread antibiotic over-agar. Equipment Pipette tips for both pipetting and spreading Bunsen burner (or other...diameter petri plate containing solidified LB-agar, pipette 150 µL of carbenicillin on top of the agar and ...liquid remaining on the surface). We use the micropipette tip itself to do the spreading; the tip is gently...same way as the antibiotic, using either a bent micropipette tip or other cell spreading device that fits...
  9. General Transfection

    Type
    Protocol
    ...single channel pipette 2–20 µL single channel pipette 20–200 µL single channel pipette 200–1000 µL single...single channel pipette Ice bucket CO 2 incubator Pipet controller Hazardous waste container Reagents DMEM...
  10. Protocol - How to Run an Agarose Gel

    Type
    Protocol
    ...is unloaded, push the pipettor to the second stop and carefully raise the pipette straight out of the buffer...comb or towards the sides/edges of the gel with a pipette tip. Place newly poured gel at 4 °C for 10-15 mins... the tip. Place the very top of the tip of the pipette into the buffer just above the well. Very slowly...needed because several microliters can be lost in pipetting. For example, if you want to load 1.0 μg in 10...
Showing: 11 - 20 of 35 results