We narrowed to 10 results for: CO
-
TypeProtocol... tissue culture plate. Incubate cells at 37°C, 5% CO 2 overnight. Although cells should regularly be passaged...cells from the plate. i. Incubate cells at 37°C, 5% CO 2 for 12-15 hours. Day 3: j. In the morning, change... transfected cells. k. Incubate cells at 37°C, 5% CO 2 for 24 hours. Day 4: l. Harvest media from cells...antibiotics to the cells and incubate at 37°C, 5% CO 2 for 24 hours. Day 5: n. Harvest media from cells...target cells in ten 6 cm plates and grow at 37°C, 5% CO 2 overnight. Day 2: b. The target cells should be...1: a. Plate target cells and incubate at 37°C, 5% CO 2 overnight. Day 2: b. Target cells should be approximately...your target cell line. d. Incubate cells at 37°C, 5% CO 2 overnight. Day 3: e. Change to fresh media 24 hours...
-
General Transfection
TypeProtocol...pipette 200–1000 µL single channel pipette Ice bucket CO 2 incubator Pipet controller Hazardous waste container...tissue culture plates. Incubate the cells at 37 °C, 5% CO 2 for ~20 h. Gently aspirate media, add 10 mL fresh... -
Lentivirus Production
TypeProtocol...pipette 200–1000 µL single channel pipette Ice bucket CO 2 incubator Pipet controller Hazardous waste container...tissue culture plates. Incubate the cells at 37 °C, 5% CO 2 for ~20 h. Prepare a mixture of the three transfection... -
Transfection for Recombinant Antibodies
TypeProtocol...mL conical tubes Automated cell counter 37 °C, 5% CO 2 incubator with shaking platform set to 120 rpm ... in a 500 mL vented flask.Incubate in a 37 °C, 5% CO 2 incubator on a shaking platform set to 120 rpm.... -
Fluorescence Titering Assay
TypeProtocol...pipette 200–1000 µL single channel pipette Ice bucket CO 2 incubator Pipet controller Hazardous waste container... -
Colony Formation Titering Assay
TypeProtocol...pipette 200–1000 µL single channel pipette Ice bucket CO 2 incubator Pipet controller Hazardous waste container... -
Virus Protocol - Generating Stable Cell Lines
TypeProtocol...pipette 200–1000 µL single channel pipette Ice bucket CO 2 incubator Pipet controller Hazardous waste container... -
Isolating a Monoclonal Cell Population by Limiting Dilution
TypeProtocol...channel pipette 200–1000 µL single channel pipette CO 2 incubator Pipet controller Hazardous waste container... -
Affinity Purification of Recombinant Antibodies with Protein A or Protein G
TypeProtocol...conical tubes NanoDrop spectrophotometer 37 °C, 5% CO 2 incubator with shaking platform set to 120 rpm ... -
AAV Production in HEK293 Cells
TypeProtocol... pipette Hemocytometer or cell counter Ice bucket CO 2 incubator Pipet controller Hazardous waste container...