Skip to main content
Addgene

We narrowed to 37 results for: des.2

Showing: 1 - 10 of 37 results
  1. Protocol - How to Design Primers

    Type
    Protocol
    ...-24 bases 40-60% G/C content Start and end with 1-2 G/C pairs Melting temperature (Tm) of 50-60°C Primer... Protocols Designing Primers How to Design a Primer You may also like...Tips on designing primers for PCR Protocols...Cloning by PCR Agarose Gel Electrophoresis Primer Design for PCR Oligonucleotide primers are necessary when... when running a PCR reaction. One needs to design primers that are complementary to the template region.... They are synthesized chemically by joining nucleotides together. One must selectively block and unblock... the primer usually has stretches of several nucleotides. Also, both of the 3’ ends of the hybridized ...
  2. What is Polymerase Chain Reaction (PCR)

    Type
    Protocol
    ...PCR tube Ice Bucket 2 μL Template DNA (10 ng-500 ng) 5 μl 10X Taq buffer with MgCl 2 1 μl dNTP mix (10 ... reagents on ice): 2 μL Template DNA (10 ng-500 ng) 5 μl 10X Taq buffer with MgCl 2 1 μl dNTP mix (10 ...normally sterile dH 2 O. To make a 100uM stock of any primer, add a number of µl of dH 2 O equal to the number...annealing temperature step-wise by 1-2°C. The rate of DNA synthesis is ~1-2 kb/min. The extension time can ...work adequately. Divalent cations such as Mg 2+ and Mn 2+ stabilize the buffer solution. These cations...Sterile dH 2 O 0.2 μL Taq DNA Polymerase (5 units/μL) PCR Machine Agarose Gel Procedure Primer Design and PCR...PCR to work efficiently. Taq Buffer with MgCl 2 : Provides an optimal and stable chemical environment for...
  3. Lab Safety for Biosafety Levels One and Two

    Type
    Protocol
    ...worn outside of the BSL-2 area. BSL-2 laboratories must be clearly marked as “BSL-2.” The names and contact...protocol provides information for both biosafety level 1 (BSL-1) and biosafety level 2 (BSL-2). The purpose...in addition to BSL-2 guidelines below, including PPE protocols . Working in a BSL-2 laboratory requires...Staphylococcus aureus or Vibrio cholerae . BSL-2 includes all of the precautions needed in BSL-1, along...pouring down the drain. Solid BSL-2 waste can be collected in designated biohazardous waste containers that... steps to ensure you are working in BSL-1 and BSL-2 labs safely. Protocols... Biosafety Levels One and Two (BSL-1 and BSL-2) Intro to the Lab Bench Check out more protocols and videos...
  4. Protocol - pLKO.1 – TRC Cloning Vector

    Type
    Protocol
    ...materials D.2 Screening for inserts E. Producing Lentiviral Particles E.1 Recommended materials E.2 Protocol...Published articles H.2 Web resources I. Appendix I.1 Sequence of pLKO.1 TRC-Cloning Vector I.2 Recipes I.3 Warranty...VWR: #7177-48-2. Use at 100 μg/mL. Carbenicillin VWR: #80030-956. Use at 100 μg/mL. C.2 Annealing Oligos...oligo 5 μL Reverse oligo 5 μL 10x NEB buffer 2 35 μL ddH 2 O Incubate for 4 minutes at 95°C in a PCR machine...buffer 1 1 μL AgeI add ddH 2 O to bring to 50 μL final volume Incubate at 37°C for 2 hours. Purify with Qiaquick...buffer for EcoRI 1 μL EcoRI 14 μL ddH 2 O Incubate at 37°C for 2 hours. Run digested DNA on 0.8% low melting... For a standard T4 ligation, mix: 2 μL annealed oligo from step C.2 20 ng digested pLKO.1 TRC-cloning ...
  5. Affinity Purification of Recombinant Antibodies with Protein A or Protein G

    Type
    Protocol
    ...phosphate monobasic monohydrate (NaH 2 PO 4 ∙H 2 O), pH 7.0 138 g NaH 2 PO 4 ∙H 2 O 1 L deionized water Adjust...sodium phosphate dibasic (NaH 2 PO 4 ), pH 7.0 142 g of NaH 2 PO 4 ∙H 2 O 1 L deionized water Adjust pH...monobasic monohydrate (NaH 2 PO 4 ∙H 2 O) 610 mL of sterile sodium phosphate dibasic (NaH 2 PO 4 ) Store up to...recombinant antibody. Section 2: Buffer exchange Choose Option 1 or Option 2 based on the concentration ... mL , then divide it into 2 columns. Twist off the 10 mL Zeba Spin Desalting Column’s bottom closure and...antibodies. Workflow Timeline Day 1: Purify antibody Day 2 or later: Buffer exchange Equipment Class II, Type...conical tubes NanoDrop spectrophotometer 37 °C, 5% CO 2 incubator with shaking platform set to 120 rpm 37 ...
  6. AAV Production in HEK293 Cells

    Type
    Protocol
    ...430825, 175 cm 2 Cellstack 5, Corning 3319, 3180 cm 2 Cellstack 2, Corning 3269, 1272 cm 2 Heat-inactivated...: 50 mM Tris HCl, 150 mM NaCl, 2 mM MgCl 2 Add the following to the 2 L sterile bottle: 1836 mL deionized... solution can be stored at 4 °C for up to 2 months. After 2 months, discard the tube and thaw a new working... mL of PBS. Aspirate PBS and add 2 mL of 0.05% Trypsin/EDTA. Wait ~2 min. Neutralize trypsin by adding...0.05% Trypsin/EDTA. Wait ~2-3 minutes for cells to detach. Gently tap the sides of the CS2 to help detach...Cell-Stack (CS5) (Link opens in a new window) (3,180 cm 2 - the same surface area as 21 x T-175 flasks). Cell...flasks. Workflow Timeline Day 0: Seed cells in CS2 Day 2: Seed cells in CS5 Day 3 (am): Transfect cells Day...
  7. AAV Titration by qPCR Using SYBR Green Technology

    Type
    Protocol
    ... 10 90 2 x 10 8 10 of 2 x 10 8 dilution 90 2 x 10 7 10 of 2 x 10 7 dilution 90 2 x 10 6 10 of 2 x 10 6...6 dilution 90 2 x 10 5 10 of 2 x 10 5 dilution 90 2 x 10 4 10 of 2 x 10 4 dilution 90 2 x 10 3 Pro-Tip...molecules/μL To obtain a solution at 2 x 10 9 molecules/μL: 1.59 x 10 11 / 2 x 10 9 = 79.8X dilution ...your standard curve plasmid (2 x 10 9 stock made in step #1): Volume of 2 x 10 9 stock or previous dilution...stock 45 uL 10X 10X Dilution 2 5 uL Dil. 1 95 uL 20X 200X Dilution 3 20 uL Dil. 2 80 uL 5X 1000X Dilution ...time required: ~3 h Workflow Timeline Plate set-up: 2 h qPCR run: 1.5 h Data analysis: 30 min Equipment ...single channel pipette 1–10 µL multichannel pipette 2–50 µL multichannel pipette 20–200 µL multichannel ...
  8. Personal Protective Equipment (PPE) for BSL-1 and BSL-2 Labs

    Type
    Protocol
    ...protocol provides information for both biosafety level 1 (BSL-1) and biosafety level 2 (BSL-2). The BSL...potential accidents such as spills. BSL-2 is different because it includes labs that work with agents associated...associated with diseases in healthy humans. BSL-2 includes all of the precautions needed in BSL-1, however...BSL-1 and BSL-2 labs. Protocols... Protocols Personal Protective Equipment (PPE) for BSL-1 and BSL-2 Labs Personal ...Personal Protective Equipment (PPE) for BSL-1 and BSL-2 Labs Intro to the Lab Bench Check out more protocols ...and/or face shields can be used as needed. For BSL-2 work always wear glasses/goggles in addition to the...
  9. General Transfection

    Type
    Protocol
    ... solution can be stored at 4 °C for up to 2 months. After 2 months, discard the tube and thaw a new working... transfected using 1:1, 1:2, 1:3 and 1:6 µg of pRosetta :µg of PEI. The 1:2 and 1:3 ratios provided high... for viral production) Day 1: Transfect Cells Day 2 (am): 18 h post transfection - Remove media, replace...Biological Safety Cabinet 0.5–10 µL single channel pipette 2–20 µL single channel pipette 20–200 µL single channel... 200–1000 µL single channel pipette Ice bucket CO 2 incubator Pipet controller Hazardous waste container... use. Thawed aliquots should be discarded after 1–2 months. 1 mg/mL polyethylenimine, linear MW 25,000...times a week: Monday: Plate 1x10 6 cells in a 75 cm 2 flask in a volume of 15 mL. Wednesday: Plate 1x10 ...
  10. Lentivirus ddPCR Titration

    Type
    Protocol
    ...Activation 95 10 2 1 Denaturation 94 0.5 2 40 Annealing/Extension 60 1 2 40 Enzyme Deactivation 98 10 2 1 Hold ...diploid cells, thus the reason for multiplying by 2. $$V = 2*{copies\ RRE \over copies\ RPP30}$$ Use the viruses...diluted 2-fold serially, the concentration of RRE positive droplets should decrease by a factor of 2 across...Lentivirus is generally considered biosafety level 2+. Please ensure that you are in compliance with your...channel pipette 200–1000 µL single channel pipette 2–50 µL multichannel pipette 20–200 µL multichannel ...Detach cells by incubating with 200 µL TrypLE for 1–2 min. Resuspend cells in 500 µL DMEM complete and transfer... DG8 cartridge into the cartridge holder. Using a 2–50 µL multichannel pipet, load 20 µL of the reaction...
Showing: 1 - 10 of 37 results