We narrowed to 40 results for: ANG
-
TypeProtocol... can scrape plates more abrasively at a certain angle. Incubate plates upside down at 30 ℃ overnight. ...DNA will vary upon intended use. Typically yields range from several hundred micrograms to a milligram of...taken to perform adequate NGS based QC to ensure no change in representation compared to the pre-amplified...
-
Weighing Reagents Protocol
TypeProtocol...material that you are weighing by looking for a weight range on the scale. Make sure that the weight of the material... material you’re weighing out is within this range. If you need less than a gram of material, use an analytical... -
Protocol - Bacterial Transformation
TypeProtocol...that will help to maintain the plasmid without rearrangement of the plasmid DNA. Additionally, specific treatments...competent cells. Pro-Tips Commercial competent cells range significantly in their transformation efficiency... -
Immunocytochemistry
TypeProtocol... antibody concentration will vary but generally ranges from 1-10 µg/mL. Add 500 µL of the diluted antibody... antibody concentration will vary but generally ranges from 1-10 µg/mL. Add 500 µL fluorescently-labeled... -
Handling Plasmids from Addgene - Purifying Plasmid DNA
TypeProtocol...much as several miligrams and at concentrations ranging from 150 ng/μL to several μg/μL. The protocol below...pellet (can be done by inverting the tube at an angle over kimwipe) for 20-30 min. Resuspend pellet with... -
What is Polymerase Chain Reaction (PCR)
TypeProtocol...reverse primers are stable within this temperature range to anneal to each of the single stranded DNA template...polymerase that can withstand radical temperature changes during a typical PCR. The DNA polymerase has an... -
AAV Production in HEK293 Cells
TypeProtocol.... Optional: perform a media exchange at ~18 h post transfection. Changing the media can reduce toxicity... -
DNA Quantification
TypeProtocol...measured under the 260/280 column (A good purity ranges from 1.80-2.00). Repeat for each sample. Notes:... -
Protocol - How to Streak a Plate
TypeProtocol... streak #1. Pro-Tips Hold your tooth pick at an angle, the way you would hold a pencil, so that you can... -
Protocol - Over-Agar Antibiotic Plating
TypeProtocol...note we have found that there is generally a broad range of antibiotic concentrations that will work for ... -
Protocol - How to Purify DNA from an Agarose Gel
TypeProtocol... gels, so you will want to stay in the 0.7-0.8% range if possible. You will want nice crisp bands. This... -
Protocol - How to Perform a Diagnostic Digest
TypeProtocol... bacterial endonucleases that recognize a large range of DNA sequences. Given the variety of these enzymes... -
Protocols for Molecular Biology, Plasmid Cloning, and Viral Preps
TypeProtocol...practical lab protocols that you can use for a wide range of applications, with videos for select protocols... -
Fluorescence Titering Assay
TypeProtocol...Data Figure 1: 293T cells were transduced with a range of dilutions of pHAGE-TO-dCas9-3XmCherry . 72 h ... -
Lab Safety for Biosafety Levels One and Two
TypeProtocol...contaminated with pathogens or chemicals that present a danger to people and the environment in biohazard containers... -
General Transfection
TypeProtocol... cells. Refer to the table below for a possible range of ratios to test: Ratio of DNA:PEI Amount of DNA... -
Lentivirus Production
TypeProtocol... cells. Refer to the table below for a possible range of ratios to test: Ratio of DNA:PEI μg of DNA μL... -
Using a Light Microscope Protocol
TypeProtocol...your cell culture dish. Microscopes come in a huge range of shapes and sizes - from phone-sized, foldable... -
Transfection for Recombinant Antibodies
TypeProtocol... determined for your sample. Typical ratios may range from 1:1 to 1:6. Add the diluted PEI-MAX to the ... -
Western Blot
TypeProtocol...Prepare serial dilutions of the BSA standard that range from 0–2000 µg/mL . In duplicate, dilute 10 µL of...